RETIFICADOR MULTIPULSOS ALIMENTADO POR GERADOR DE ÍMÃ PERMANENTE – ANÁLISE DO CONTEÚDO HARMÔNICO PRÉ-EXISTENTE

Falcondes J. M. de Seixas, Rodolfo C. Fernandes, Priscila S. Oliveira

Abstract


The present paper proposes the analysis of apermanent magnet generator (PMG) considering theinfluence of its harmonic levels in multipulse rectifiers. Noloadand full-load experiments were carried out in order tocreate a PMG model, which includes its leakage reactanceand total harmonic distortion (THD). Four different 12-pulse structures are designed, simulated and comparedregarding weight, volume and need of interphasetransformers. A 12-pulse rectifier, comprising a 4.2kWisolated Y/Δ-Y transformer with series connected outputs,was built and tested together with the PMG, showing 11.5%THD, for both voltage and current in the primary of thetransformer.

 

 

Index Terms - permanent magnet generator, multipulse rectifier.


Full Text: PDF

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution 3.0 License.

----------------------------------------------------------------------

ISSN 2317-4145

----------------------------------------------------------------------

Indexing

Logotipo do IBICT

----------------------------------------------------------------------

Scientific Societies and Directories

Logotipo COPEC Logotipo SHERO Logotipo da Capes

----------------------------------------------------------------------

Follow Us

Logotipo facebook Logotipo LinkedIn Logotipo Twitter